UV disinfection system calculator

Select the UV unit model based on the flow to treat and the dose required by the application: conventional disinfection, NSF 61, or ozone and TOC reduction.

Input data

Sizing results

—Selected model
—Unit flow (GPM)
—Total power (W)

Selected unit

Parameters

Feed water requirements (AquaUV data sheet)
UV transmittance (UVT)> 75 %
Suspended solids< 10 mg/L
Iron< 0.3 mg/L
Manganese< 0.05 mg/L
Hardness< 120 mg/L
Tannins< 0.3 mg/L
pH6,5 – 9,5
ColorNone
Ambient temperature2 – 40 °C
Maximum pressure8.6 bar (125 psi)

Nominal flows assume UVT > 75%. With lower-transmittance water, the flow per unit must be reduced.

Results are for reference and intended for pre-design. Our engineering team validates every design with the water analysis and the actual project conditions.

Would you like us to validate your design?

Send us the calculator results and your water analysis. We will propose the right equipment, with local installation and technical service.